Port 3FD - Line status register
1xxx xxxx Forced to 0
x1xx xxxx 1=TEMT (Transmitter Empty)
The transmit shift and hold registers are empty
xx1x xxxx 1=THRE (Transmitter Holding Register Empty)
Indicates that a new character can be send.
Set when character send.
xxx1 xxxx 1=BI (Break Interrupt)
Set when connection could be lost. Reset when register
read.
xxxx 1xxx 1=FE (Framing Error)
Set when last character didn't have a valid stop bit.
Reset when register read.
xxxx x1xx 1=PE (Parity Error)
Reset when register read.
xxxx xx1x 1=OE (Overrun Error)
Set when data is received and buffer (port 3D8)
isn't empty. Reset when register is read.
xxxx xxx1 1=DR (Data Ready)
Set when data is received
Reset when port 3F8 is read.
Note: Bit 1 through 4 are error conditions that produce a Receive
Line Status Interrupt whenever any of the corresponding conditions
are detected.
Note: This is a Read-Only register. Writing is not recommended,
as this operation is used for factory testing.